Precision Thickness Micrometer (Dead Weight Type) Specification
- Mounting Type
- Bench-top
- Automation Grade
- Manual
- Equipment Type
- Precision Thickness Micrometer (Dead Weight Type)
- Max Height
- Approx. 250 mm
- Measuring Range
- 0-10 mm
- Test Range
- 0 - 10 mm
- Number of Specimens
- 1 at a time
- Features
- Adjustable Dead Weights, Smooth Lever Operation, High Precision
- Power Supply
- Not Required (Manual Operation)
- Accuracy
- 0.01 mm
- Display Type
- Dial Gauge or Digital (Optional)
- Resolution
- 0.001 mm
- Response Time
- Immediate (Manual)
- Application
- Precise Thickness Measurement for Paper, Films, Rubber, Plastics, Textiles, etc.
- Specimen Size
- Minimum 50 mm x 50 mm
- Temperature
- 15C to 40C
- Interface Type
- None/Manual
- Humidity
- Up to 85% RH (Non-Condensing)
- Usage
- Laboratory and Industrial
- Capacity
- Dead Weights Provided for Standard Loads
- Machine Weight
- Approx. 12 kg
- Test Speed
- Manual (Dead Weight driven)
- Test Width
- 50 mm
- Test Stroke
- Up to 10 mm
- Control Mode
- Dead Weight Operation
- Anvil Diameter
- 10 mm (Flat, Polished)
- Finish
- Powder Coated / Plated
- Contact Pressure
- 1 N (Standard, as per customer requirement)
- Dead Weight Set
- Supplied as per customer/application need
- Packing
- Export-worthy Wooden Box
- Dial Gauge Type
- Fine Graduation, Shock-proof
- Operating Environment
- Clean, Dust-free Laboratory
- Material of Construction
- Mild Steel / SS (Base Plate & Frame), Hardened Steel (Contact Surfaces)
Precision Thickness Micrometer (Dead Weight Type) Trade Information
- Minimum Order Quantity
- 1 Unit
- Supply Ability
- 20 Units Per Week
- Delivery Time
- 4 Week
- Main Domestic Market
- All India
About Precision Thickness Micrometer (Dead Weight Type)
Versatile Applications and Simple Usage
The Precision Thickness Micrometer (Dead Weight Type) excels in laboratory and industrial settings for precise thickness measurement across a range of surfaces, including paper, plastics, rubber, textiles, and films. Its manual dead weight-driven operation allows easy application, requiring minimal setup for single specimen testing. The highly polished flat anvil guarantees reliable contact, making it perfect for clean laboratory environments. Bench-top mounting ensures stability while the adjustable dead weights suit diverse material requirements.
Domestic Market and Seamless Delivery
Within the main domestic markets of India, customers can place a purchase order for the Precision Thickness Micrometer with the assurance of secure shipping and prompt delivery times. Each unit is expertly packed in export-worthy wooden boxes, safeguarding the instrument during transit to your facility. Manufacturers and suppliers ensure swift dispatch following order confirmation and efficient response to bulk or wholesale requests. Reliability and product integrity are prioritized for every domestic shipment.
FAQs of Precision Thickness Micrometer (Dead Weight Type):
Q: How do I operate the Precision Thickness Micrometer (Dead Weight Type)?
A: Simply place your specimen on the base plate, adjust the dead weights to the required contact pressure, and use the smooth lever for accurate manual measurement. The dial gauge or digital display will show the exact thickness instantly.Q: What surfaces can be measured with this instrument?
A: This micrometer is designed for versatile applications and can measure paper, films, rubber, plastics, and textiles with high precision. Its flat, polished anvil ensures consistent contact for reliable results.Q: When should I use manual dead weight operation over automatic devices?
A: Manual dead weight operation is ideal for environments prioritizing control, accuracy, and simplicity, such as laboratories with limited power supply or where test conditions need strict adherence to standards.Q: Where can the Precision Thickness Micrometer be installed?
A: It is best mounted on a stable bench-top in a clean, dust-free laboratory or industrial workspace, ensuring optimal measurement accuracy and ease of use.Q: What are the benefits of the adjustable dead weights?
A: Adjustable dead weights allow users to customize contact pressure based on specimen type, ensuring precision and compliance with specific measurement standards or customer requirements.Q: How is the instrument packaged for delivery?
A: Each Precision Thickness Micrometer is shipped in a secure, export-quality wooden box, protecting the device from damage during transportation and handling.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Adhesive Testing Category
Internal Plybond Tester-Digital
Price 250000 INR / Number
Minimum Order Quantity : 01 Number, ,
Machine Weight : Approx. 20 kg
Application : Paper, Paperboard and Packaging Material Plybond Strength Measurement
Equipment Type : Internal Plybond Tester Digital
Usage : Lab Testing, Quality Inspection
Laboratory Seal Peal Strength Tester
Machine Weight : Approx. 45 kg
Application : Seal, Peal, and Adhesion Strength testing of Packaging & Film
Equipment Type : Peel Strength Tester
Usage : Laboratory Packaging Test
Precision Thickness Micrometer
Price 22000 INR / Unit
Minimum Order Quantity : 1 Unit
Machine Weight : Approx. 1.8 kg
Application : Precise measurement of paper, film, fabric, rubber and other flat materials
Equipment Type : Precision Thickness Micrometer
Usage : Laboratory, Industrial
Thickness Micrometer
Price 93000.00 INR / Number
Minimum Order Quantity : 1 Number
Machine Weight : 28 Kilograms (kg)
Application : Industrial
Equipment Type : Measuring Equipment
Usage : Industrial measurement of material thickness
![]() |
GLOBAL ENGINEERING CORPORATION
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |





Send Inquiry